FISH- CLL Panel

FISH- CLL Panel (HCSLHCLL) WSLH Cytogenetics Lab Test

Name: FISH- CLL Panel

Test Name: FISH- CLL Panel

Health Link Test Code: HCSLHCLL

LIS Test Code: SLHCLL

CPT Code(s): 88271x5, 88275x4

Test Component:

870F40- 11q22 deletion/duplication, FISH, ATM gene

870F43- Deletion 13q14, FISH, D13S319

870F47- Deletion 17p13.1, FISH, TP53

870F51- Trisomy 12, FISH, D12Z3

 

See individual tests for more information.

Methodology: Fluorescence In Situ Hybridization (FISH)

Clinical Information:

Aids in diagnosis of hematologic disorders and for monitoring disease after treatment or bone marrow transplant.

Testing Site: Testing will be sent to an approved reference laboratory

Days Performed: Mon-Sat.

In-Lab Turnaround Time: 3 - 5 days.

Specimen: Blood or bone marrow

Collection Container: Green top (with sodium heparin anticoagulant)

Collection Instructions:

Blood or bone marrow must be received and processed by WSLH within 24 hours of collection. Specimen must be received in UWHC Hospital Laboratory Monday-Friday only.

Collection Volume: 2-3 mL blood or 0.5-1.0 mL bone marrow

Stability Ambient:

24 hours

Stability Refridgerated:

Not acceptable

Stability Frozen:

Not acceptable

Sample Analyzed: Whole Blood or Bone Marrow

Specimen Transport:

Transport specimen at room temperature to UWHC Hospital Laboratory. Transport with coolant pack during hot weather (>85°F).

Unacceptable Criteria:

Bone marrow/blood that is clotted or hemolyzed.

Interpretation:

Interpretation provided with results.

Test Limitations:

Failure to identify an abnormal clone by FISH does not rule out the presence of other abnormalities in the specimen.

Additional Information:

If FISH assay is not performed in conjunction with chromosome analysis there is an additional charge for processing the specimen.